Viron Inverter iHP90 Side Discharge HP

Viron Side Discharge Inverter

Product information

SKU wh000618

Product description

AstralPool Viron Inverter Side Discharge Heat Pump is environmentally friendly with new inverter technology to save cost. It also include wifi module for you to access it remotely.

- Environmentally friendly - Wi-Fi module included - Whisper quiet - Super Efficient - Low operating Costs

Specifications

  • Air 27°C / Water 26°C / Humidity 80% Heating Capacity (kW): 1.83-8.31
  • Air 27°C / Water 26°C / Humidity 80% Consumed power (kW): 0.13-1.54
  • Air 27°C / Water 26°C / Humidity 80% COP: 14-5.39
  • Air 15°C / Water 26°C / Humidity 70% Heating Capacity (kW): 1.49-6.82
  • Air 15°C / Water 26°C / Humidity 70% Consumed power (kW): 0.24-1.61
  • Air 15°C / Water 26°C / Humidity 70% COP: 6.21-4.23
  • Air 35°C / Water 29°C / Humidity 70% Cooling Capacity (kW): 1.92-3.5
  • Air 35°C / Water 29°C / Humidity 70% Consumed power (kW): 0.48-1.14
  • Air 35°C / Water 29°C / Humidity 70% EER: 4.0-3.07
  • Power Supply: 220-240V / 50Hz
  • Power Phase: Single phase
  • Airflow (m2/hr): 1400-2000
  • Rated Current (A): 9.5
  • Sound Pressure 1m dBA: 32.2-47.8
  • Sound Pressure 10m dBA: 307-36.3
  • Water Connections (mm): 50
  • Water Flow Volume (LPM): 61
  • Net Dimensions L/W/H (mm): 1000 x 430 x 625
  • Net Weight (kg): 56
  • Compressor Brand: Mitsubishi
  • Operating Air Temperature (deg.C): -7°C ~ 43°C
  • Refrigerant: R32

Product information

  • Brand: astralpool-nz
  • SKU: wh000618
Viron Side Discharge

Product information

Energy Efficient

For every 1 kW of electricity consumed, AstralPool Heat Pumps will collect up to 13 kW of heat from the atmosphere. Sunshine is not necessary and your Heat Pump will continue to heat your pool in air temperatures as low as 7 degrees. So even if the nights are cold, or the days leading up to the weekend are cool, your AstralPool Heat Pump can heat and maintain your pool water temperature at a comfortable swimming temperature.

Built for Australian environments

Unlike many other heat pumps, the corrosion proof titanium heat exchanger is enclosed in a purpose designed and fully injection moulded housing for maximum strength and long life. The fully moulded plastic Heat Pump case is impervious to corrosion and guarantees maximum life regardless of location, “seaside” tropical north or outback.

Quiet compressor

A nearly silent compressor moves the refrigerant gas through a coil (called evaporator) through which air is forced and collects heat from the surrounding atmosphere. The now superheated refrigerant gas then passes through a titanium heat exchanger (called a condenser) which transfers the heat into the pool water and the cycle starts again.

Environmentally friendly

AstralPool Heat Pumps are an environmentally friendly option to heat your pool. Operating on a similar principle to your refrigerator or air conditioner, Heat Pumps use environmentally friendly refrigerant gas that extracts the latent heat from the air and transfers this heat into the pool water.

Air 27°C / Water 26°C / Humidity 80% Heating Capacity (kW)
wh000618
1.83-8.31
wh000619
2.3-11
wh000620
2.8-16.1
Air 27°C / Water 26°C / Humidity 80% Consumed power (kW)
wh000618
0.13-1.54
wh000619
0.16-1.95
wh000620
0.19-2.9
Air 27°C / Water 26°C / Humidity 80% COP
wh000618
14-5.39
wh000619
14.2-5.5
wh000620
14.5-5.6
Air 15°C / Water 26°C / Humidity 70% Heating Capacity (kW)
wh000618
1.49-6.82
wh000619
1.82-8.00
wh000620
2.3-12.76
Air 15°C / Water 26°C / Humidity 70% Consumed power (kW)
wh000618
0.24-1.61
wh000619
0.26-1.95
wh000620
0.34-2.99
Air 15°C / Water 26°C / Humidity 70% COP
wh000618
6.21-4.23
wh000619
7.0-4.10
wh000620
6.76-4.26
Air 35°C / Water 29°C / Humidity 70% Cooling Capacity (kW)
wh000618
1.92-3.5
wh000619
2.06-3.65
wh000620
2.50-4.54
Air 35°C / Water 29°C / Humidity 70% Consumed power (kW)
wh000618
0.48-1.14
wh000619
0.50-1.29
wh000620
0.85-2.01
Air 35°C / Water 29°C / Humidity 70% EER
wh000618
4.0-3.07
wh000619
4.12-2.83
wh000620
2.94-2.26
Power Supply
wh000618
220-240V / 50Hz
wh000619
220-240V / 50Hz
wh000620
220-240V / 50Hz
Power Phase
wh000618
Single phase
wh000619
Single phase
wh000620
Single phase
Airflow (m2/hr)
wh000618
1400-2000
wh000619
1400-2300
wh000620
3000-3800
Rated Current (A)
wh000618
9.5
wh000619
10.3
wh000620
14
Sound Pressure 1m dBA
wh000618
32.2-47.8
wh000619
32.2-48.2
wh000620
40.8-52.4
Sound Pressure 10m dBA
wh000618
307-36.3
wh000619
307-36.7
wh000620
23.9-35.5
Water Connections (mm)
wh000618
50
wh000619
50
wh000620
50
Water Flow Volume (LPM)
wh000618
61
wh000619
76
wh000620
110
Net Dimensions L/W/H (mm)
wh000618
1000 x 430 x 625
wh000619
1000 x 430 x 625
wh000620
1020 x 480 x 768
Net Weight (kg)
wh000618
56
wh000619
57
wh000620
76
Compressor Brand
wh000618
Mitsubishi
wh000619
Mitsubishi
wh000620
Mitsubishi
Operating Air Temperature (deg.C)
wh000618
-7°C ~ 43°C
wh000619
-7°C ~ 43°C
wh000620
-7°C ~ 43°C
Refrigerant
wh000618
R32
wh000619
R32
wh000620
R32
Brochures
  • AstralPool Heat Pump Inverter Range Catalogue - Brochure

Manuals